Thank you for your effort @DomiStyle 👍
Works with VKW Honeywell DM515 smart meter using the following config:
esphome: name: vkw-waerme platform: ESP32 board: az-delivery-devkit-v4 includes: - ./esphome-dlms-meter # Enable logging logger: level: INFO # tx_buffer_size: 2048 # Only needed when logging large packets # Enable Home Assistant API if not using MQTT #api: # password: "1234" # reboot_timeout: 0s ota: - platform: esphome password: "" wifi: ssid: "xxx" password: "xxx" output_power: 8.5dB # Enable fallback hotspot (captive portal) in case wifi connection fails ap: ssid: "xxx" password: "xxx" #web_server: # port: 80 uart: tx_pin: GPIO16 #changed as recommend in other issue and on https://www.libe.net/smart-meter rx_pin: GPIO35 #changed as recommend in other issue and on https://www.libe.net/smart-meter baud_rate: 2400 rx_buffer_size: 2048 # Needed to receive the large packets send by the smart meter id: mbus sensor: - platform: template id: meter01_voltage_l1 name: meter01_voltage_l1 unit_of_measurement: V accuracy_decimals: 1 device_class: "voltage" state_class: "measurement" - platform: template id: meter01_voltage_l2 name: meter01_voltage_l2 unit_of_measurement: V accuracy_decimals: 1 device_class: "voltage" state_class: "measurement" - platform: template id: meter01_voltage_l3 name: meter01_voltage_l3 unit_of_measurement: V accuracy_decimals: 1 device_class: "voltage" state_class: "measurement" - platform: template id: meter01_current_l1 name: meter01_current_l1 unit_of_measurement: A accuracy_decimals: 2 device_class: "current" state_class: "measurement" - platform: template id: meter01_current_l2 name: meter01_current_l2 unit_of_measurement: A accuracy_decimals: 2 device_class: "current" state_class: "measurement" - platform: template id: meter01_current_l3 name: meter01_current_l3 unit_of_measurement: A accuracy_decimals: 2 device_class: "current" state_class: "measurement" - platform: template id: meter01_active_power_plus name: meter01_active_power_plus unit_of_measurement: W accuracy_decimals: 0 device_class: "power" state_class: "measurement" - platform: template id: meter01_active_power_minus name: meter01_active_power_minus unit_of_measurement: W accuracy_decimals: 0 device_class: "power" state_class: "measurement" - platform: template id: meter01_active_energy_plus name: meter01_active_energy_plus unit_of_measurement: Wh accuracy_decimals: 0 device_class: "energy" state_class: "total_increasing" - platform: template id: meter01_active_energy_minus name: meter01_active_energy_minus unit_of_measurement: Wh accuracy_decimals: 0 device_class: "energy" state_class: "total_increasing" - platform: template id: meter01_reactive_energy_plus name: meter01_reactive_energy_plus unit_of_measurement: Wh accuracy_decimals: 0 device_class: "energy" state_class: "total_increasing" - platform: template id: meter01_reactive_energy_minus name: meter01_reactive_energy_minus unit_of_measurement: Wh accuracy_decimals: 0 device_class: "energy" state_class: "total_increasing" text_sensor: - platform: template id: meter01_timestamp name: meter01_timestamp mqtt: broker: "192.168.1.xxx" port: "1883" id: mqtt_broker username: 'xxx' password: 'xxx' discovery: true custom_component: - lambda: |- auto dlms_meter = new esphome::espdm::DlmsMeter(id(mbus)); uint8_t key[] = {0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00}; dlms_meter->set_key(key, 16); // Pass your decryption key and key length here dlms_meter->set_voltage_sensors(id(meter01_voltage_l1), id(meter01_voltage_l2), id(meter01_voltage_l3)); // Set sensors to use for voltage (optional) dlms_meter->set_current_sensors(id(meter01_current_l1), id(meter01_current_l2), id(meter01_current_l3)); // Set sensors to use for current (optional) dlms_meter->set_active_power_sensors(id(meter01_active_power_plus), id(meter01_active_power_minus)); // Set sensors to use for active power (optional) dlms_meter->set_active_energy_sensors(id(meter01_active_energy_plus), id(meter01_active_energy_minus)); // Set sensors to use for active energy (optional) dlms_meter->set_reactive_energy_sensors(id(meter01_reactive_energy_plus), id(meter01_reactive_energy_minus)); // Set sensors to use for reactive energy (optional) dlms_meter->set_timestamp_sensor(id(meter01_timestamp)); // Set sensor to use for timestamp (optional) dlms_meter->enable_mqtt(id(mqtt_broker), "meter01/data"); // Enable grouped together MQTT report, useful to get exact time with each data for storing results in InfluxDB return {dlms_meter};
The text was updated successfully, but these errors were encountered:
No branches or pull requests
Thank you for your effort @DomiStyle 👍
Works with VKW Honeywell DM515 smart meter using the following config:
The text was updated successfully, but these errors were encountered: