Working with VKW Honeywell DM515 #44

Open
g0mml opened this issue Sep 22, 2024 · 0 comments
Open

Working with VKW Honeywell DM515 #44

g0mml opened this issue Sep 22, 2024 · 0 comments

Comments

@g0mml
Copy link

g0mml commented Sep 22, 2024

Thank you for your effort @DomiStyle 👍

Works with VKW Honeywell DM515 smart meter using the following config:

esphome:
  name: vkw-waerme
  platform: ESP32
  board: az-delivery-devkit-v4
  includes:
    - ./esphome-dlms-meter

# Enable logging
logger:
  level: INFO
#  tx_buffer_size: 2048 # Only needed when logging large packets

# Enable Home Assistant API if not using MQTT
#api:
#  password: "1234"
#  reboot_timeout: 0s


ota:
  - platform: esphome
    password: ""

wifi:
  ssid: "xxx"
  password: "xxx"
  output_power: 8.5dB

  # Enable fallback hotspot (captive portal) in case wifi connection fails
  ap:
    ssid: "xxx"
    password: "xxx"


#web_server:
#  port: 80

uart:
  tx_pin: GPIO16 #changed as recommend in other issue and on https://www.libe.net/smart-meter
  rx_pin: GPIO35 #changed as recommend in other issue and on https://www.libe.net/smart-meter
  baud_rate: 2400
  rx_buffer_size: 2048 # Needed to receive the large packets send by the smart meter
  id: mbus

sensor:
  - platform: template
    id: meter01_voltage_l1
    name: meter01_voltage_l1
    unit_of_measurement: V
    accuracy_decimals: 1
    device_class: "voltage"
    state_class: "measurement"
  - platform: template
    id: meter01_voltage_l2
    name: meter01_voltage_l2
    unit_of_measurement: V
    accuracy_decimals: 1
    device_class: "voltage"
    state_class: "measurement"
  - platform: template
    id: meter01_voltage_l3
    name: meter01_voltage_l3
    unit_of_measurement: V
    accuracy_decimals: 1
    device_class: "voltage"
    state_class: "measurement"

  - platform: template
    id: meter01_current_l1
    name: meter01_current_l1
    unit_of_measurement: A
    accuracy_decimals: 2
    device_class: "current"
    state_class: "measurement"
  - platform: template
    id: meter01_current_l2
    name: meter01_current_l2
    unit_of_measurement: A
    accuracy_decimals: 2
    device_class: "current"
    state_class: "measurement"
  - platform: template
    id: meter01_current_l3
    name: meter01_current_l3
    unit_of_measurement: A
    accuracy_decimals: 2
    device_class: "current"
    state_class: "measurement"

  - platform: template
    id: meter01_active_power_plus
    name: meter01_active_power_plus
    unit_of_measurement: W
    accuracy_decimals: 0
    device_class: "power"
    state_class: "measurement"
  - platform: template
    id: meter01_active_power_minus
    name: meter01_active_power_minus
    unit_of_measurement: W
    accuracy_decimals: 0
    device_class: "power"
    state_class: "measurement"

  - platform: template
    id: meter01_active_energy_plus
    name: meter01_active_energy_plus
    unit_of_measurement: Wh
    accuracy_decimals: 0
    device_class: "energy"
    state_class: "total_increasing"
  - platform: template
    id: meter01_active_energy_minus
    name: meter01_active_energy_minus
    unit_of_measurement: Wh
    accuracy_decimals: 0
    device_class: "energy"
    state_class: "total_increasing"

  - platform: template
    id: meter01_reactive_energy_plus
    name: meter01_reactive_energy_plus
    unit_of_measurement: Wh
    accuracy_decimals: 0
    device_class: "energy"
    state_class: "total_increasing"
  - platform: template
    id: meter01_reactive_energy_minus
    name: meter01_reactive_energy_minus
    unit_of_measurement: Wh
    accuracy_decimals: 0
    device_class: "energy"
    state_class: "total_increasing"

text_sensor:
  - platform: template
    id: meter01_timestamp
    name: meter01_timestamp

mqtt:
  broker: "192.168.1.xxx"
  port: "1883"
  id: mqtt_broker
  username: 'xxx'
  password: 'xxx'
  discovery: true

custom_component:
  - lambda: |-
      auto dlms_meter = new esphome::espdm::DlmsMeter(id(mbus));
      uint8_t key[] = {0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00};
      dlms_meter->set_key(key, 16); // Pass your decryption key and key length here

      dlms_meter->set_voltage_sensors(id(meter01_voltage_l1), id(meter01_voltage_l2), id(meter01_voltage_l3)); // Set sensors to use for voltage (optional)

      dlms_meter->set_current_sensors(id(meter01_current_l1), id(meter01_current_l2), id(meter01_current_l3)); // Set sensors to use for current (optional)

      dlms_meter->set_active_power_sensors(id(meter01_active_power_plus), id(meter01_active_power_minus)); // Set sensors to use for active power (optional)

      dlms_meter->set_active_energy_sensors(id(meter01_active_energy_plus), id(meter01_active_energy_minus)); // Set sensors to use for active energy (optional)
      dlms_meter->set_reactive_energy_sensors(id(meter01_reactive_energy_plus), id(meter01_reactive_energy_minus)); // Set sensors to use for reactive energy (optional)

      dlms_meter->set_timestamp_sensor(id(meter01_timestamp)); // Set sensor to use for timestamp (optional)

      dlms_meter->enable_mqtt(id(mqtt_broker), "meter01/data"); // Enable grouped together MQTT report, useful to get exact time with each data for storing results in InfluxDB

      return {dlms_meter};