Configuring Management Interface On Server Node

  1. Modify interface configuration files on both nodes as under:
    srvnode-1: /etc/sysconfig/network-scripts/ifcfg-eno2

    TYPE=Ethernet
    PROXY_METHOD=none
    BROWSER_ONLY=no
    BOOTPROTO=none
    DEFROUTE=no
    IPV4_FAILURE_FATAL=no
    IPV6INIT=no
    IPV6_DEFROUTE=no
    IPV6_FAILURE_FATAL=no
    IPV6_ADDR_GEN_MODE=stable-privacy
    DEVICE=eno2
    ONBOOT=yes
    IPADDR=10.0.0.4
    NETMASK=255.255.255.0
    

    srvnode-2: /etc/sysconfig/network-scripts/ifcfg-eno2

    TYPE=Ethernet
    PROXY_METHOD=none
    BROWSER_ONLY=no
    BOOTPROTO=none
    DEFROUTE=no
    IPV4_FAILURE_FATAL=no
    IPV6INIT=no
    IPV6_DEFROUTE=no
    IPV6_FAILURE_FATAL=no
    IPV6_ADDR_GEN_MODE=stable-privacy
    DEVICE=eno2
    ONBOOT=yes
    IPADDR=10.0.0.5
    NETMASK=255.255.255.0
    
  2. Restart the 1GBps interface with direct cable connection to Enclosure ethernet port
    E.g. For eno1 one must run commands:

    ifdown eno-2  
    ifup eno-2  
    
  3. Verify the IP assignment with command:

    ip a  
    

    Note: Look for the same network interface that was configured in #1

Configure Static IP On Storage Enclosure

Follow step #2 from guide: https://github.com/Seagate/cortx-prvsnr/wiki/In-band-Setup#RBOD-side