Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

vPC peering aware run for dcnm_link | vpc peering link prepare | backlog | Good to have #88

Open
rrahimm opened this issue May 2, 2024 · 0 comments
Labels
enhancement New feature or request

Comments

@rrahimm
Copy link
Collaborator

rrahimm commented May 2, 2024

We currently use dcnm_links module to prepare links for vpc_peering. and we use the policy "int_pre_provision_intra_fabric_link" for preparing the links.

once this is done and vpc_pairing module pairs the switches, the policy is changed from int_pre_provision_intra_fabric_link to none.

Before Example

[
{
    "link-uuid": "LINK-UUID-375050",
    "is-present": false,
    "link-type": "lan_planned_link",
    "is-discovered": false,
    "is-planned": true,
    "sw2-info": 
{},
"link-dbid": 531270,
"nvPairs": 
{},
"policyId": "POLICY-531280",
"templateName": "int_pre_provision_intra_fabric_link",
"is-port-channel": false,
"sw1-info": 
    {},
    "fabricName": "netascode_fabric4"
},

After Example

{
    "link-uuid": "LINK-UUID-105050",
    "is-present": true,
    "link-type": "ethisl",
    "is-discovered": false,
    "is-planned": false,
    "sw2-info": 
{},
"link-dbid": 510380,
"is-port-channel": false,
"sw1-info": 

    {},
    "port-channel-id": 510670
},

Due to this, everytime we eun the dcnm_links its no more behaving as idempotent and keeps trying to pull the template back to "int_pre_provision_intra_fabric_link" (it doesn't seem to succeed though).

Rerun of dcnm_links for a already provisioned vpc peer link

TASK [cisco.nac_dc_vxlan.create : Manage Intra Fabric Links for vpc peering] *****************************************************************************
changed: [netascode_fabric4] => {
    "changed": true,
    "diff": [
        {
            "debugs": [
                {
                    "Managable": {
                        "192.168.112.1": "9K5ACTZ6071",
                        "192.168.112.151": "9C1V52BBBX5",
                        "192.168.112.152": "9GFVGDY6DOA",
                        "192.168.112.2": "9U6ZZHH0M5G",
                        "192.168.112.3": "9GRR0AIPIRU",
                        "192.168.112.4": "9OI0P2LZKND",
                        "netascode4-leaf1": "9K5ACTZ6071",
                        "netascode4-leaf2": "9U6ZZHH0M5G",
                        "netascode4-leaf3": "9GRR0AIPIRU",
                        "netascode4-leaf4": "9OI0P2LZKND",
                        "netascode4-spine1": "9C1V52BBBX5",
                        "netascode4-spine2": "9GFVGDY6DOA"
                    }
                },
                {
                    "Monitoring": []
                }
            ],
            "deleted": [],
            "deploy": [
                {
                    "netascode_fabric4": [
                        "9K5ACTZ6071",
                        "9U6ZZHH0M5G",
                        "9GRR0AIPIRU",
                        "9OI0P2LZKND"
                    ]
                }
            ],
            "merged": [
                {
                    "destinationDevice": "9U6ZZHH0M5G",
                    "destinationFabric": "netascode_fabric4",
                    "destinationInterface": "Ethernet1/3",
                    "destinationSwitchName": "netascode4-leaf2",
                    "sourceDevice": "9K5ACTZ6071",
                    "sourceFabric": "netascode_fabric4",
                    "sourceInterface": "Ethernet1/3",
                    "sourceSwitchName": "netascode4-leaf1",
                    "templateName": "int_pre_provision_intra_fabric_link"
                },
                {
                    "destinationDevice": "9U6ZZHH0M5G",
                    "destinationFabric": "netascode_fabric4",
                    "destinationInterface": "Ethernet1/4",
                    "destinationSwitchName": "netascode4-leaf2",
                    "sourceDevice": "9K5ACTZ6071",
                    "sourceFabric": "netascode_fabric4",
                    "sourceInterface": "Ethernet1/4",
                    "sourceSwitchName": "netascode4-leaf1",
                    "templateName": "int_pre_provision_intra_fabric_link"
                },
                {
                    "destinationDevice": "9U6ZZHH0M5G",
                    "destinationFabric": "netascode_fabric4",
                    "destinationInterface": "Ethernet1/5",
                    "destinationSwitchName": "netascode4-leaf2",
                    "sourceDevice": "9K5ACTZ6071",
                    "sourceFabric": "netascode_fabric4",
                    "sourceInterface": "Ethernet1/5",
                    "sourceSwitchName": "netascode4-leaf1",
                    "templateName": "int_pre_provision_intra_fabric_link"
                },
                {
                    "destinationDevice": "9OI0P2LZKND",
                    "destinationFabric": "netascode_fabric4",
                    "destinationInterface": "Ethernet1/3",
                    "destinationSwitchName": "netascode4-leaf4",
                    "sourceDevice": "9GRR0AIPIRU",
                    "sourceFabric": "netascode_fabric4",
                    "sourceInterface": "Ethernet1/3",
                    "sourceSwitchName": "netascode4-leaf3",
                    "templateName": "int_pre_provision_intra_fabric_link"
                }
            ],
            "modified": [],
            "query": []
        }
    ],
    "invocation": {
        "module_args": {
            "config": [
                {
                    "dst_device": "192.168.112.2",
                    "dst_fabric": "netascode_fabric4",
                    "dst_interface": "Ethernet1/3",
                    "src_device": "192.168.112.1",
                    "src_interface": "Ethernet1/3",
                    "template": "int_pre_provision_intra_fabric_link"
                },
                {
                    "dst_device": "192.168.112.2",
                    "dst_fabric": "netascode_fabric4",
                    "dst_interface": "Ethernet1/4",
                    "src_device": "192.168.112.1",
                    "src_interface": "Ethernet1/4",
                    "template": "int_pre_provision_intra_fabric_link"
                },
                {
                    "dst_device": "192.168.112.2",
                    "dst_fabric": "netascode_fabric4",
                    "dst_interface": "Ethernet1/5",
                    "src_device": "192.168.112.1",
                    "src_interface": "Ethernet1/5",
                    "template": "int_pre_provision_intra_fabric_link"
                },
                {
                    "dst_device": "192.168.112.4",
                    "dst_fabric": "netascode_fabric4",
                    "dst_interface": "Ethernet1/3",
                    "src_device": "192.168.112.3",
                    "src_interface": "Ethernet1/3",
                    "template": "int_pre_provision_intra_fabric_link"
                }
            ],
            "deploy": true,
            "src_fabric": "netascode_fabric4",
            "state": "replaced"
        }
    },
    "response": [
        {
            "DATA": {
                "linkUUID": "LINK-UUID-8380",
                "status": "Success"
            },
            "MESSAGE": "OK",
            "METHOD": "POST",
            "REQUEST_PATH": "https://10.195.225.172:443/appcenter/cisco/ndfc/api/v1/lan-fabric/rest/control/links",
            "RETURN_CODE": 200
        },
        {
            "DATA": {
                "linkUUID": "LINK-UUID-8400",
                "status": "Success"
            },
            "MESSAGE": "OK",
            "METHOD": "POST",
            "REQUEST_PATH": "https://10.195.225.172:443/appcenter/cisco/ndfc/api/v1/lan-fabric/rest/control/links",
            "RETURN_CODE": 200
        },
        {
            "DATA": {
                "linkUUID": "LINK-UUID-105050",
                "status": "Success"
            },
            "MESSAGE": "OK",
            "METHOD": "POST",
            "REQUEST_PATH": "https://10.195.225.172:443/appcenter/cisco/ndfc/api/v1/lan-fabric/rest/control/links",
            "RETURN_CODE": 200
        },
        {
            "DATA": {
                "linkUUID": "LINK-UUID-9920",
                "status": "Success"
            },
            "MESSAGE": "OK",
            "METHOD": "POST",
            "REQUEST_PATH": "https://10.195.225.172:443/appcenter/cisco/ndfc/api/v1/lan-fabric/rest/control/links",
            "RETURN_CODE": 200
        },
        {
            "DATA": {
                "status": "Configuration deployment completed."
            },
            "MESSAGE": "OK",
            "METHOD": "POST",
            "REQUEST_PATH": "https://10.195.225.172:443/appcenter/cisco/ndfc/api/v1/lan-fabric/rest/control/fabrics/netascode_fabric4/config-deploy/9K5ACTZ6071,9U6ZZHH0M5G,9GRR0AIPIRU,9OI0P2LZKND",
            "RETURN_CODE": 200
        },
        {
            "DATA": [
                {
                    "briefCount": 0,
                    "deployMode": "config",
                    "diff": null,
                    "entityList": [],
                    "expectedConfig": [],
                    "fabricName": null,
                    "pendingConfig": [],
                    "runningConfig": [],
                    "status": "In-Sync",
                    "statusDesc": "In-Sync",
                    "switchId": "9GRR0AIPIRU",
                    "switchMgmtIP": "192.168.112.3",
                    "switchName": "netascode4-leaf3",
                    "switchRole": "leaf"
                },
                {
                    "briefCount": 0,
                    "deployMode": "config",
                    "diff": null,
                    "entityList": [],
                    "expectedConfig": [],
                    "fabricName": null,
                    "pendingConfig": [],
                    "runningConfig": [],
                    "status": "In-Sync",
                    "statusDesc": "In-Sync",
                    "switchId": "9K5ACTZ6071",
                    "switchMgmtIP": "192.168.112.1",
                    "switchName": "netascode4-leaf1",
                    "switchRole": "leaf"
                },
                {
                    "briefCount": 0,
                    "deployMode": "config",
                    "diff": null,
                    "entityList": [],
                    "expectedConfig": [],
                    "fabricName": null,
                    "pendingConfig": [],
                    "runningConfig": [],
                    "status": "In-Sync",
                    "statusDesc": "In-Sync",
                    "switchId": "9U6ZZHH0M5G",
                    "switchMgmtIP": "192.168.112.2",
                    "switchName": "netascode4-leaf2",
                    "switchRole": "leaf"
                },
                {
                    "briefCount": 0,
                    "deployMode": "config",
                    "diff": null,
                    "entityList": [],
                    "expectedConfig": [],
                    "fabricName": null,
                    "pendingConfig": [],
                    "runningConfig": [],
                    "status": "In-Sync",
                    "statusDesc": "In-Sync",
                    "switchId": "9OI0P2LZKND",
                    "switchMgmtIP": "192.168.112.4",
                    "switchName": "netascode4-leaf4",
                    "switchRole": "leaf"
                }
            ],
            "MESSAGE": "OK",
            "METHOD": "GET",
            "REQUEST_PATH": "https://10.195.225.172:443/appcenter/cisco/ndfc/api/v1/lan-fabric/rest/control/fabrics/netascode_fabric4/config-preview/9K5ACTZ6071,9U6ZZHH0M5G,9GRR0AIPIRU,9OI0P2LZKND?forceShowRun=false&showBrief=true",
            "RETURN_CODE": 200
        }
    ]
}

The action is to add intelligence to the prepare link task to skip dcnm_link preparation when the vpc is already paired.

@rrahimm rrahimm added the enhancement New feature or request label May 2, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
enhancement New feature or request
Projects
None yet
Development

No branches or pull requests

1 participant