Use of GT labels to calculate classificaiton threshold at test time #16

Closed
anissa218 opened this issue Nov 19, 2024 · 1 comment
Closed

Comments

@anissa218
Copy link

Hi, it seems like you use the ground truth test labels (tol_target) to find the optimal classification threshold, and subsequently determine accuracy, FNR, FPR etc.

@ys-zong
Copy link
Owner

ys-zong commented Jan 16, 2025

Hi. The main metric (AUC) used throughout the paper does not require a threshold. For metrics that require a threshold such as Acc, FNR etc., the implementation follows these two papers: https://www.nature.com/articles/s41591-021-01595-0, and https://arxiv.org/pdf/2203.12609 (sec 4) as acknowledged in the code.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment