Read total length from .end_of_bowden_to_sensor when loading to nozzle #91
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Had an issue ( #82 ) where ERCF would fault when loading filament from reverse bowden to the toolhead sensor, but shortly after would say "Filament loaded successfully". Thought this might have been a timing issue initially, but I was able to add the end_of_bowden_to_sensor variable to the load length and this stopped the fault from happening.