Identifies each conduit arc of the drainage system.
Column name | Data type | Description | Domain values |
---|---|---|---|
arc_id | character varying(50) | Id of arc | |
barrels | smallint | Number of barrels associated with a conduit | |
culvert | character varying(10) | Code number for the conduit’s inlet geometry if it is a culvert subject to possible inlet flow control | |
kentry | numeric(12,4) | Entrance minor head loss coefficient | |
kexit | numeric(12,4) | Exit minor head loss coefficient | |
kavg | numeric(12,4) | Average minor head loss coefficient across length of conduit | |
flap | character varying(3) | YES if conduit has a flap valve that prevents back flow, NO otherwise. | [YES, NO] |
q0 | numeric(12,4) | Flow in conduit at start of simulation | |
qmax | numeric(12,4) | Maximum flow allowed in the conduit | |
seepage | numeric(12,4) | Seepage losses for conduits | |
custom_n | numeric(12,4) | Customized manning coefficient (this value overwrites manning’s value defined for material) |