add heatpump section; move tariffs to top level #703
Open
naltatis
wants to merge
6
commits into
main
Choose a base branch
from
feature/add_heatpump
base: main
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Open
Changes from all commits
Commits
Show all changes
6 commits
Select commit
Hold shift + click to select a range
bb2917f
add heatpump section; move tariffs to top level
naltatis a4ce117
sg ready diagram
naltatis a87795a
docs
naltatis b3dca6f
fixes, english translation
naltatis 18f77e9
integrated device
naltatis b118a13
Update heating.mdx
premultiply File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,256 @@ | ||
--- | ||
sidebar_position: 3 | ||
--- | ||
|
||
import Tabs from "@theme/Tabs"; | ||
import TabItem from "@theme/TabItem"; | ||
import SponsorshipRequired from "/docs/_sponsorship_required.mdx"; | ||
import PhaseSwitchSupported from "/docs/_phase_switch_supported.mdx"; | ||
import DeviceConfig from "/src/components/DeviceConfig"; | ||
import DeviceFeatures from "/src/components/DeviceFeatures"; | ||
|
||
# Wärmepumpen, Heizstäbe | ||
|
||
:::warning In Entwicklung | ||
Das Thema Wärmeerzeugung ist noch in der Erprobungsphase.<br/> | ||
Für die hier aufgeführten Geräte wird später ein [Sponsoring erforderlich](/docs/sponsorship) sein. | ||
::: | ||
|
||
evcc unterstützt unterschiedliche Arten von Wärmeerzeugern. | ||
Einfache Geräte wie Heizlüfter oder Ventilatoren können über [Smarte Schalter](./smartswitches) ein/ausgeschaltet werden. | ||
Auf dieser Seite erfährst du, wie du auch **Wärmepumpen** oder **Heizstäbe** steuern kannst. | ||
|
||
## Wärmepumpen | ||
|
||
Viele Wärmepumpen unterstützen das SG-Ready-Modell, um ihren Betrieb an die Energiesituation vor Ort anzupassen. | ||
Darüber lassen sich bis zu vier vordefinierte, bei manchen Modellen auch frei konfigurierbare Szenarien ansteuern. | ||
Neben dem **Normalbetrieb** kann darüber von außen ein **verstärkter Betrieb (Boost)**, ein **reduzierter Betrieb** und ein **Sperrbetrieb** signalisiert werden. | ||
|
||
Ist [Überschussstrom vorhanden](/docs/features/solar-charging) oder der [Netzstrom besonders günstig](/docs/features/dynamic-prices) bzw. [sauber](/docs/features/co2), kann evcc die Wärmepumpe anweisen, die Heizleistung zu erhöhen und in den **verstärkten Betrieb (Boost)** zu schalten. | ||
|
||
Die Funktion für den reduzierten Betrieb oder den Sperrbetrieb wird bisher nicht unterstützt. | ||
Wir planen dies ggf. über das [Lastmanagement](/docs/features/loadmanagement) zu integrieren. | ||
Damit könnten - je nach Modell - ggf. auch Anforderungen nach §14a EnWG abgedeckt werden. | ||
|
||
### direkte Kommunikation | ||
|
||
Viele moderne Wärmepumpen bieten API-Schnittstellen an, über die nicht nur der Betriebsmodus gesetzt, sondern auch der Zustand des Gerätes (z.B. Leistungsaufnahme, Temperaturen) abgefragt werden kann. | ||
Unter [Wärmeerzeuger](#wärmeerzeuger) findest du eine Liste aller unterstützten Geräte. | ||
|
||
Sollte deine Wärmepumpe eine Schnittstelle haben, die wir noch nicht unterstützen, erstelle gerne ein [GitHub Issue](https://github.com/evcc-io/evcc/issues) mit allen notwendigen Informationen. | ||
|
||
### über Relais-Kontakte | ||
|
||
Ältere Wärmepumpen verfügen häufig über SG-Ready Relais-Kontakte, über die der gewünschte Betriebszustand signalisiert werden kann. | ||
In unserem Beispiel konzentrieren wir uns auf den Wechsel zwischen Normal- und Boostbetrieb. | ||
Hierfür wird ein steuerbares Relais verwendet, bpsw. ein Shelly 1. | ||
|
||
Dieses Relais wird mit den SG-Ready Kontakten der Wärmepumpe verbunden. | ||
Die genaue Verkabelung, die notwendige Logik und auch die Konfiguration hängt vom Gerät ab und sollte in Absprache mit dem Installateur erfolgen. | ||
Ist PV-Überschuss oder günstige Energie vorhanden, schaltet evcc das Relais und gibt der Wärmepumpe das Signal für den verstärkten Betrieb (Boost). | ||
Letztendlich entscheidet das Gerät aber abhängig vom aktuellen Betriebszustand und seiner Konfiguration immer selbst ob und wieweit es diesem Wunsch auch tatsächlich entsprechen wird. | ||
|
||
Das folgende Diagramm zeigt den Aufbau: | ||
|
||
![Diagram für die Steuerung einer Wärmepumpe über ein SG-Ready Relais](./heating/sgready.svg) | ||
|
||
Möchtest du die Leistung und den Energieverbrauch der Wärmepumpe genau erfassen, kannst du optional einen Zähler an der Stromversorgung des Geräts installieren. | ||
Dies empfiehlt sich eigentlich fast immer, da die intern ermittelten Daten bei den meisten Modellen am Markt auf Schätzwerten und nicht Messungen basieren oder nicht den Energiebedarf aller Komponenten erfassen. | ||
Im Diagram ist ein Shelly 3EM dargestellt, hier kann aber ein beliebiger [Zähler](./meters) verwendet werden. | ||
|
||
Dieses Code-Beispiel zeigt, wie du eine Wärmepumpe mittels Shelly 1 und Shelly 3EM konfigurieren kannst. | ||
Dafür kommt der spezielle Typ `sgready` zum Einsatz. | ||
|
||
```yaml | ||
loadpoints: | ||
- title: Meine Wärmepumpe | ||
charger: heatpump_control | ||
meter: heatpump_power | ||
integrateddevice: true # Fahrzeugauswahl deaktivieren | ||
|
||
meters: | ||
- name: heatpump_power | ||
type: template | ||
template: shelly-3em # Stromverbrauch der Wärmepumpe | ||
host: 192.168.0.102 | ||
|
||
chargers: | ||
- name: heatpump_control | ||
type: sgready | ||
setmode: | ||
source: switch | ||
switch: | ||
- case: 1 # normal | ||
set: | ||
source: const | ||
value: false | ||
set: | ||
source: charger | ||
config: | ||
type: template | ||
template: shelly # Boost-Kontakt der Wärmepumpe | ||
host: 192.168.0.101 | ||
- case: 2 # boost | ||
set: | ||
source: const | ||
value: true | ||
set: | ||
source: charger | ||
config: | ||
type: template | ||
template: shelly # Boost-Kontakt der Wärmepumpe | ||
host: 192.168.0.101 | ||
- case: 3 # dimm (not supported, yet) | ||
set: | ||
source: error | ||
error: ErrNotAvailable | ||
getmode: | ||
source: calc | ||
add: | ||
- source: const | ||
value: 1 | ||
- source: charger | ||
config: | ||
type: template | ||
template: shelly # Boost-Kontakt der Wärmepumpe | ||
host: 192.168.0.101 | ||
# temp: | ||
# source: http | ||
# uri: "http://192.168.0.103/temperature" | ||
|
||
# [...] | ||
naltatis marked this conversation as resolved.
Show resolved
Hide resolved
|
||
``` | ||
|
||
:::note | ||
Dieses Code-Beispiel enthält einige Redundanzen. | ||
Wir werden später Templates für die einfachere Konfiguration gängiger Konstellationen bereitstellen. | ||
::: | ||
|
||
Neben `setmode` und `getmode`, kannst du optional auch die aktuelle Temperatur (`temp`) [via Plugin](/docs/reference/plugins) hinzufügen. | ||
Diese dient lediglich zur Anzeige und wird bei Wärmepumpen nicht für die Steuerung verwendet. | ||
|
||
## Heizstäbe | ||
|
||
Normale Heizstäbe können von evcc nur an- oder abgeschaltet werden. Dazu werden diese in der Regel über eine [schaltbare Steckdose](./smartswitches) angeschlossen. | ||
evcc aktiviert dann bei ausreichend Überschussleistung diese Steckdose (Freigabe) und deaktiviert diese wieder sobald die Bedingungen es erfordern (Sperre). | ||
|
||
Bei speziellen Heizstäben mit eigener stufenloser Steuerung gibt evcc die aktuell verfügbare Leistung an das Gerät weiter. | ||
Diese verfügbare Leistung wird, analog zum Ladevorgang eines Fahrzeuges, permanent an die aktuelle Situation angepasst. | ||
|
||
evcc bietet einstellbare Limits an, mit denen du optional deine Wunschtemperatur einstellen kannst. | ||
Dies darf aber nicht als Sicherheitsfunktion verstanden werden. | ||
|
||
Normalerweise sollte die Temperaturregelung ausschließlich über die Thermostatfunktion des Heizstabs selbst erfolgen. | ||
|
||
:::danger | ||
Dein Heizstab muss immer eine eigene Temperaturbegrenzung mitbringen, die bei einer eventuellen Fehlfunktion/Ausfall von evcc oder einer Fehlbedienung eine unzulässige Überhitzung sicher ausschließt. | ||
::: | ||
|
||
|
||
|
||
--- | ||
|
||
<!-- AUTO-GENERATED CONTENT BELOW THIS LINE --> | ||
|
||
<!-- AUTO-GENERATED FROM TEMPLATE - PLEASE EDIT HERE https://github.com/evcc-io/evcc/tree/master/templates/definition/heating --> | ||
|
||
## Wärmeerzeuger | ||
|
||
### my-PV AC ELWA 2 | ||
|
||
<DeviceConfig code={`chargers: | ||
- name: my_heating | ||
type: template | ||
template: ac-elwa-2 | ||
|
||
# Modbus TCP | ||
modbus: tcpip | ||
id: 1 | ||
host: 192.0.2.2 # Hostname | ||
port: 502 # Port`} /> | ||
|
||
|
||
|
||
<SponsorshipRequired /> | ||
|
||
<!-- AUTO-GENERATED FROM TEMPLATE - PLEASE EDIT HERE https://github.com/evcc-io/evcc/tree/master/templates/definition/heating --> | ||
|
||
### Stiebel Eltron | ||
|
||
#### LWA/LWZ (SG Ready) | ||
|
||
<DeviceConfig code={`chargers: | ||
- name: my_heating | ||
type: template | ||
template: stiebel-lwa | ||
|
||
# Modbus TCP | ||
modbus: tcpip | ||
id: 1 | ||
host: 192.0.2.2 # Hostname | ||
port: 502 # Port | ||
tempsource: # optional`} /> | ||
|
||
|
||
|
||
<!-- AUTO-GENERATED FROM TEMPLATE - PLEASE EDIT HERE https://github.com/evcc-io/evcc/tree/master/templates/definition/heating --> | ||
|
||
#### WPM (SG Ready) | ||
|
||
<DeviceConfig code={`chargers: | ||
- name: my_heating | ||
type: template | ||
template: stiebel-wpm | ||
|
||
# Modbus TCP | ||
modbus: tcpip | ||
id: 1 | ||
host: 192.0.2.2 # Hostname | ||
port: 502 # Port | ||
tempsource: # optional`} /> | ||
|
||
|
||
|
||
<!-- AUTO-GENERATED FROM TEMPLATE - PLEASE EDIT HERE https://github.com/evcc-io/evcc/tree/master/templates/definition/heating --> | ||
|
||
### Tecalor THZ (SG Ready) | ||
|
||
<DeviceConfig code={`chargers: | ||
- name: my_heating | ||
type: template | ||
template: stiebel-lwa | ||
|
||
# Modbus TCP | ||
modbus: tcpip | ||
id: 1 | ||
host: 192.0.2.2 # Hostname | ||
port: 502 # Port | ||
tempsource: # optional`} /> | ||
|
||
|
||
|
||
<!-- AUTO-GENERATED FROM TEMPLATE - PLEASE EDIT HERE https://github.com/evcc-io/evcc/tree/master/templates/definition/heating --> | ||
|
||
### Vaillant SensoNET (SG Ready) | ||
|
||
Die Boost Funktion erwärmt Warmwasser und optional eine Boostzone. Die Boostzone wird durch die ID identifiziert. Die Boost Temperatur wird in Grad Celsius angegeben. | ||
|
||
<DeviceConfig code={`chargers: | ||
- name: my_heating | ||
type: template | ||
template: vaillant | ||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (optional) | ||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (optional) | ||
zone: # Id der Boostzone (zusätzlich zu Warmwasser) (optional) | ||
setpoint: # Boost Temperatur (zusätzlich zu Warmwasser) (optional)`} advanced={`chargers: | ||
- name: my_heating | ||
type: template | ||
template: vaillant | ||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (optional) | ||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (optional) | ||
zone: # Id der Boostzone (zusätzlich zu Warmwasser) (optional) | ||
setpoint: # Boost Temperatur (zusätzlich zu Warmwasser) (optional) | ||
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können (optional)`} /> | ||
|
||
|
||
|
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Das ist zumindest bei mir anders.