10 changes: 5 additions & 5 deletions API.md
Original file line number Diff line number Diff line change
Expand Up @@ -44,8 +44,8 @@
| `awpl`<br>`awattarPriceList` | Awattar Price List | R/W | `array`<br>`array` | Status | :white_large_square: | awattar price list, timestamps are measured in unix-time, seconds since 1970 | `[{"start": 1650567600, "end": 1650571200, "marketprice": 22.044}, {"start": 1650571200, "end": 1650574800, "marketprice": 19.971}]` |
| `bac`<br>`buttonAllowCurrentChange` | Button Allow Current Change | R/W | `boolean`<br>`bool` | Config | :heavy_check_mark: | Button allow Current change | `true` |
| `bam`<br>- | | | `boolean`<br>- | | :white_large_square: | | `true` |
| `cae`<br>- | | | `boolean`<br>- | | :white_large_square: | | `false` |
| `cak`<br>- | | | `string`<br>- | | :white_large_square: | | `""` |
| `cae`<br>`cloudApiEnable` | Cloud API Enable | R/W | `boolean`<br>`bool` | | :white_large_square: | Set to true, if you want to use the go-eCharger API at https://<serial number>.api.v3.go-e.io/api. | `false` |
| `cak`<br>`cloudApiKey` | Cloud API Key | R/W | `string`<br>`string` | | :white_large_square: | Contains the access token (32 characters) for the cloud API. Whenever you write anything to cak a new token is generated automatically. | `"Cjk4BWbH8EcTFtY6dsWvTYz6CjBxifeO"` |
| `car`<br>`carState` | Car State | R | `integer`<br>`optional<uint8>` | Status | :heavy_check_mark: | carState, null if internal error (Unknown/Error=0, Idle=1, Charging=2, WaitCar=3, Complete=4, Error=5) | `1` |
| `cards`<br>`registeredCards` | Registered Cards | R/W | `array`<br>`array` | | :white_large_square: | Registered RFID cards for different users | `[{"name": "User 1", "energy": 0, "cardId": true}, {"name": "User 2", "energy": 0, "cardId": false}]` |
| `cbl`<br>`cableCurrentLimit` | Cable Current Limit | R | `integer`<br>`optional<int>` | Status | :heavy_check_mark: | cable_current_limit in A | `20` |
Expand Down Expand Up @@ -99,7 +99,7 @@
| `etop`<br>`energyTotalPersisted` | Energy Total Persisted | R | `integer`<br>`uint64` | Status | :heavy_check_mark: | energy_total persisted, measured in Wh, without the extra magic to have live values | `1076098` |
| `facwak`<br>`factoryWifiApKey` | Factory Wifi AP Key | R | `string`<br>`string` | Constant | :white_large_square: | WiFi AccessPoint Key RESET VALUE (factory) | `true` |
| `fam`<br>`pvBatteryLimit` | PV Battery Limit | | `integer`<br>- | | :white_large_square: | Battery limit for PV surplus charging | `20` |
| `fap`<br>- | | | `boolean`<br>- | | :white_large_square: | | `false` |
| `fap`<br>`froniusAllowPause` | Fronius Allow Pause | R/W | `boolean`<br>`bool` | | :white_large_square: | Normally true. Set to false if your car disconnects when a charging pause occurs. Only VW ID.3/ID.4 seem to require this. | `false` |
| `fbuf_age`<br>`fbufAge` | Fronius Age | | `integer`<br>- | | :white_large_square: | | `93639347` |
| `fbuf_akkuMode`<br>`akkuMode` | Battery Mode | | `integer`<br>- | | :white_large_square: | | `1` |
| `fbuf_akkuSOC`<br>`akkuSoc` | Battery SoC | | `float`<br>- | | :heavy_check_mark: | State of charge of the PV battery | `72.5` |
Expand Down Expand Up @@ -134,10 +134,10 @@
| `fsp`<br>`forceSinglePhase` | Force Single Phase | R/W | `boolean`<br>`bool` | Status | :white_large_square: | force_single_phase (shows if currently single phase charge is enforced) | `false` |
| `fsptws`<br>`forceSinglePhaseToggleWishedSince` | Force Single Phase Toggle Wished Since | R | `integer`<br>`optional<milliseconds>` | Status | :white_large_square: | force single phase toggle wished since | `28771782` |
| `fst`<br>`startingPower` | Starting Power | R/W | `float`<br>`float` | Config | :heavy_check_mark: | startingPower in watts. This is the minimum power at which charging can be started. | `1400` |
| `fte`<br>- | | | `integer`<br>- | | :white_large_square: | | `50000` |
| `fte`<br>`froniusTripEnergy` | Fronius Trip Energy | R/W | `integer`<br>`int` | | :white_large_square: | Minimum energy in Watthours to charge in next trip mode. | `50000` |
| `ftlf`<br>- | | | `boolean`<br>- | | :white_large_square: | | `false` |
| `ftls`<br>- | | | `unknown`<br>- | | :white_large_square: | | `null` |
| `ftt`<br>- | | | `integer`<br>- | | :white_large_square: | | `25200` |
| `ftt`<br>`froniusTripTime` | Fronius Trip Time | R/W | `integer`<br>`int` | | :white_large_square: | Starting time of your next trip in seconds from midnight local time. 3600 = 01:00 am local time | `25200` |
| `ful`<br>`useDynamicPricing` | useDynamicPricing | | `boolean`<br>- | | :white_large_square: | Uses dynamic electricity pricing (Lumina, aWattar) | `false` |
| `fup`<br>`usePvSurplus` | PV Surplus | R/W | `boolean`<br>`bool` | Config | :white_large_square: | Use PV surplus charging | `true` |
| `fwan`<br>`factoryWifiApName` | Factory WiFi AP Name | R | `string`<br>`string` | Constant | :white_large_square: | factoryWifiApName | `"Wattpilot_<some_serialnr>"` |
Expand Down
27 changes: 26 additions & 1 deletion src/wattpilot/ressources/wattpilot.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -454,11 +454,21 @@ properties:
jsonType: boolean
example: true
- key: cae
alias: cloudApiEnable
title: Cloud API Enable
description: Set to true, if you want to use the go-eCharger API at https://<serial number>.api.v3.go-e.io/api.
jsonType: boolean
example: false
rw: R/W
type: bool
- key: cak
alias: cloudApiKey
title: Cloud API Key
description: Contains the access token (32 characters) for the cloud API. Whenever you write anything to cak a new token is generated automatically.
jsonType: string
example: ""
example: "Cjk4BWbH8EcTFtY6dsWvTYz6CjBxifeO"
rw: R/W
type: string
- key: car
alias: carState
title: Car State
Expand Down Expand Up @@ -1107,8 +1117,13 @@ properties:
example: 20
description: Battery limit for PV surplus charging
- key: fap
alias: froniusAllowPause
title: Fronius Allow Pause
description: Normally true. Set to false if your car disconnects when a charging pause occurs. Only VW ID.3/ID.4 seem to require this.
jsonType: boolean
example: false
rw: R/W
type: bool
- key: fbuf_age
alias: fbufAge # TODO: Bad guess - may change!
title: Fronius Age
Expand Down Expand Up @@ -1372,17 +1387,27 @@ properties:
max: 11000
step: 100
- key: fte
alias: froniusTripEnergy
title: Fronius Trip Energy
description: Minimum energy in Watthours to charge in next trip mode.
jsonType: integer
example: 50000
rw: R/W
type: int
- key: ftlf
jsonType: boolean
example: false
- key: ftls
jsonType: unknown
example: null
- key: ftt
alias: froniusTripTime
title: Fronius Trip Time
description: Starting time of your next trip in seconds from midnight local time. 3600 = 01:00 am local time
jsonType: integer
example: 25200
rw: R/W
type: int
- key: ful
alias: useDynamicPricing
title: useDynamicPricing
Expand Down